2-Aminobutylamino-4-ethylamino-6-isopropylamino- 1,3,5-triazine (ABA-atrazine) has been synthesized and used as a coating hapten in an immunoassay with a monoclonal antibody against terbutryn. Coating was achieved by covalently linking ABA-atrazine to a glutaraldehyde polymer network directly bound to the polystyrene surface of a standard 96-well microtiter plate. The assay was carefully optimized. In particular, the coating hapten concentration had a strong effect on the ELISA sensitivity. By including a pre-incubation step a low test midpoint (IC50-value) of 0.130 mug L-1 was achieved. As far as we are aware this is the most sensitive ELISA for terbutryn yet reported. The coating-hapten-forinat presented is proposed as generally applicable, because the glutaraldehyde-modified microtiter plate surface enables stable immobilization of a broad variety of coating haptens.