4.7 Review

Predicting success in weaning from mechanical ventilation

期刊

CHEST
卷 120, 期 6, 页码 400S-424S

出版社

AMER COLL CHEST PHYSICIANS
DOI: 10.1378/chest.120.6_suppl.400S

关键词

extubation; mechanical ventilation; meta-analysis; methods; modes; reintubation; systematic reviews; weaning

资金

  1. PHS HHS [290-97-0017] Funding Source: Medline

向作者/读者索取更多资源

We identified 65 observational studies of weaning predictors that had been reported in 70 publications. After grouping predictors with similar names but different thresholds, the following predictors met our relevance criteria: heterogeneous populations, 51; COPD patients, 21; and cardiovascular ICU patients, 45. Many variables were of no use in predicting the results of weaning. Moreover, few variables had been studied in > 50 patients or had results presented to generate estimates of predictive power. For stepwise reductions in mechanical support, the most promising predictors were a rapid shallow breathing index (RSBI) < 65 breaths/min/L (measured using the ventilator settings that were in effect at the time that the prediction was made) and a pressure time product < 275 cm H2O/L/s. The pooled likelihood ratios (LRs) were 1.1 (95% confidence interval [CI], 0.95 to 1.28) for a respiratory rate [RR] of < 38 breaths/min and 0.32 (95% CI, 0.06 to 1.71) for an RR of > 38 breaths/min, which indicate that an RR of < 38 breaths/min leaves the probability of successful weaning virtually unchanged but that a value of > 38 breaths/min leads to a small reduction in the probability of success in weaning the level of mechanical support. For trials of unassisted breathing, the most promising weaning predictors include the following: RR; RSBI; a product of RSBI and occlusion pressure < 450 cm H2O breaths/min/L; maximal inspiratory pressure (PImax) < 20 cm H2O; and a knowledge-based system for adjusting pressure support. Pooled results for the power of a positive test result for both RR and RSBI were limited (highest LR, 2.23), while the power of a negative test result was substantial (ie, LR, 0.09 to 0.23). Summary data suggest a similar predictive power for RR and RSBI. In the prediction of successful extubation, an RR of < 38 breaths/min (sensitivity, 88%; specificity, 47%), an RSBI < 100 or 105 breaths/min/L (sensitivity, 65 to 96%; specificity, 0 to 73%), PImax, and APACHE (acute physiology and chronic health evaluation) II scores that are obtained at hospital admission appear to be the most promising. After pooling, two variables appeared to have some value. An RR of > 38 breaths/min and an RSBI of > 100 breaths/min/L appear to reduce the probability of successful extubation, and PImax < 0.3, for which the pooled LR is 2.23 (95% CI, 1.15 to 4.34), appears to marginally increase the likelihood of successful extubation. judging by areas under the receiver operator curve for all variables, none of these variables demonstrate more than modest accuracy in predicting weaning outcome. Why do most of these tests perform so poorly? The likely explanation is that clinicians have already considered the results when they choose patients for trials of weaning.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据