4.8 Article

Lead phthalocyanine as a selective carrier for preparation of a cysteine-selective electrode

期刊

ANALYTICAL CHEMISTRY
卷 73, 期 24, 页码 5972-5978

出版社

AMER CHEMICAL SOC
DOI: 10.1021/ac010541m

关键词

-

向作者/读者索取更多资源

A novel cysteine-selective electrode based on lead phthalocyanine (PbPc) as ionophore is described. The electrode was prepared by incorporating PbPc into a plasticized poly(vinyl chloride) (PVC) membrane, which was directly coated on the surface of a graphite electrode. This electrode shows high selectivity for the response to cysteine, as compared with many common inorganic anions, salicylate, and other kinds of amino acids. The influence of membrane composition, pH, and the effect of lipophilic cationic and anionic additives on the response characteristics of the electrode were investigated. The resulting sensor demonstrates nernstian response over a wide linear range of cysteine concentration (1 X 10(-6) to 5 X 10(-2) M). The electrode has a fast response time, micromolar detection limit (similar to1 x 10(-6) M), and good longterm stability (more than I month). The prepared electrode was used for determination of cysteine in a synthetic human serum sample, and very good recovery results were obtained over a wide concentration range of cysteine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据