期刊
ANESTHESIA AND ANALGESIA
卷 94, 期 4, 页码 781-786出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00000539-200204000-00003
关键词
-
Potential overestimation of plasma volume (PV) determination by the conventional indocyanine green (ICG) dilution method (PV-ICG) can occur when generalized capillary protein leakage is present, because ICG binds to proteins. We recently reported that this overestimation can be recognized by simultaneous measurement of the initial distribution volume of glucose (IDVG). We examined whether overestimation of PV-ICG and further ICG-pulse dye densitometry-derived plasma volume (PV-PDD) can occur early after cardiac surgery by using the PV-ICG/IDVG ratio as an indica tor. Possible overestimation was defined as a ratio higher than 0.45. Twenty-four consecutive postcardiac surgical patients were enrolled. PV-ICG, PV-PDD, and IDVG were calculated simultaneously after admission to the intensive care unit and on the first postoperative day. The mean +/- SD PV-ICG/IDVG ratio for 47 recordings was 0.38 +/- 0.05. Four had a PV-ICG/IDVG ratio higher than 0.45, and the highest was 0.48. The mean PV-PDD/IDVG ratio for a total of 47 recordings was 0.39 +/- 0.10. There were extremely high or low ratios observed in PV-PDD determinations, but they were not observed in PV-ICG determinations. Results suggest that most of the PV-ICG measurements are accurate, but inaccuracy of PV-PDD can occur early after cardiac surgery.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据