4.5 Review

Protein disulfide bond determination by mass spectrometry

期刊

MASS SPECTROMETRY REVIEWS
卷 21, 期 3, 页码 183-216

出版社

WILEY
DOI: 10.1002/mas.10025

关键词

disulfide bonds; O-18-labeling; MALDI-TOF-MS; MALDI-PSD; electrospray-MSIMS

向作者/读者索取更多资源

The determination of disulfide bonds is an important aspect of gaining a comprehensive understanding of the chemical structure of a protein. The basic strategy for obtaining this information involves the identification of disulfide-linked peptides in digests of proteins and the characterization of their half-cystinyl peptide constituents. Tools for disulfide bond analysis have improved dramatically in the past two decades, especially in terms of speed and sensitivity. This improvement is largely due to the development of matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), and complementary analyzers with high resolution and accuracy. The process of pairing half-cystinyl peptides is now generally achieved by comparing masses of non-reduced and reduced aliquots of a digest of a protein that was proteolyzed with intact disulfide bonds. Pepsin has favorable properties for generating disulfide-linked peptides, including its acidic pH optimum, at which disulfide bond rearrangement is precluded and protein conformations are likely to be unfolded and accessible to cleavage, and broad substrate specificity. These properties potentiate cleavage between all half-cystine residues of the substrate protein. However pepsin produces complex digests that contain overlapping peptides due to ragged cleavage. This complexity can produce very complex spectra and/or hamper the ionization of some constituent peptides. It may also be more difficult to compute which half-cystinyl sequences of the protein of interest are disulfide-linked in non-reduced peptic digests. This ambiguity is offset to some extent by sequence tags that may arise from ragged cleavages and aid sequence assignments. Problems associated with pepsin cleavage can be minimized by digestion in solvents that contain 50% (H2O)-O-18. Resultant disulfide-linked peptides have distinct isotope profiles (combinations of isotope ratios and average mass increases) compared to the same peptides with only 160 in their terminal carboxylates. Thus, it is possible to identify disulfide-linked peptides in digests and chromatographic fractions, using these mass-specific markers, and to rationalize mass changes upon reduction in terms of half-cystinyl sequences of the protein of interest. Some peptides may require additional cleavages due to their multiple disulfide bond contents and/or tandem mass spectrometry (MS/MS) to determine linkages. Interpretation of the MS/MS spectra of peptides with multiple disulfides in supplementary digests is also facilitated by the presence of 180 in their terminal carboxylates. (C) 2002 Wiley Periodicals, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据