期刊
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS
卷 41, 期 5B, 页码 3248-3249出版社
INST PURE APPLIED PHYSICS
DOI: 10.1143/JJAP.41.3248
关键词
ultrasound; sonoluminescence; sonochemistry; simultaneous observation; single bubble; cavitation; acoustic radiation pressure; light-scattering method
This paper describes a method of simultaneously executing both observations using a charge-coupled device (CCD) camera with stroboscopic light and measurement of bubble radius with light scattering. This optical system consists of a beam splitter inserted between a lens and the CCD camera, and a photomultiplier tube (PMT) mounted at the beam splitter. It is confirmed that this system is useful for the simultaneous observation of the bubble size, shape and translational motion.