Simultaneous determination of eight β-blockers by gradient high-performance liquid chromatography with combined ultraviolet and fluorescence detection in corneal permeability studies in vitro

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S1570-0232(02)00059-4

关键词

beta-blockers

向作者/读者索取更多资源

A gradient HPLC method with combined ultraviolet and fluorescence detection was developed for the simultaneous determination of eight beta-blockers (alprenolol, atenolol, metoprolol, nadolol, pindolol, propranolol, sotalol and timolol) in corneal permeability studies in vitro. Fluorescence detection with excitation wavelength at 230 nm and emission at 302 nm was selective for six of the compounds, whereas UV detection at 205 nm was able to detect all the compounds. Calibration was performed with fluorescence detection for six compounds from 50 or 200 nM to 3 muM and with UV detection for all the eight compounds from 100 or 200 nM to 30 muM. With optimized fluorescence detection, detection limits between 0.7 and 1.3 nM (0.035-0.065 pmol per 50 mul injection) were obtained for atenolol, metoprolol, nadolol and sotalol. A mixture of eight beta-blockers was used in cassette dosing permeability studies with a cultured corneal epithelium. The HPLC method revealed marked differences in the permeation between hydrophilic and lipophilic beta-blockers through the corneal epithelial cell culture model. (C) 2002 Elsevier Science B.V. All rights reserved.