4.8 Article

A glucose biosensor based on microporous polyacrylonitrile synthesized by single rare-earth catalyst

期刊

BIOSENSORS & BIOELECTRONICS
卷 17, 期 6-7, 页码 541-545

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/S0956-5663(02)00010-6

关键词

polyacrylonitrile; glucose oxidase; biosensor; enzyme electrode; rare-earth catalyst

向作者/读者索取更多资源

A glucose biosensor was constructed by electrochemical adsorption of glucose oxidase (GOD) in microporous polyacrylonitrile (PAN), which was synthesized by single rare-earth catalyst-Y(OAr)(3). The biosensor shows a fast response, good operational stability and reproducibility. The influences of molecular weight of polymer, pH, operating potential and temperature on the biosensor response were explored by amperometric method. The apparent activation energy and optimum pH of enzyme-catalyzed reaction are 35.9 kJ mol(-1) and 6.2, respectively. (C) 2002 Elsevier Science BY. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据