期刊
CHEMOSPHERE
卷 48, 期 3, 页码 275-278出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0045-6535(02)00085-1
关键词
arsenic; chromium; speciation; HPLC; AAS
The speciation of arsenic [As(III) and As(V)] and chromium [Cr(III) and Cr(VI)] was carried out by high performance liquid chromatography. The column used was Econosil C-18 (250 x 4.6 mm i.d., particle size 10 mum). The mobile phases consisted of water-acetonitrile (80:20, v/v) for arsenic and 10 mM ammonium acetate buffer (6.0 pH)-acetonitrile (10:90, v/v) for chromium speciation separately and respectively. The detection was carried out by UV-Vis at 410 nm and atomic absorption spectrometer (AAS) respectively and separately. The values of alpha and R-s of As(III) and As(V) species were 1.4 and 1.5 respectively while the values of alpha and R-s for Cr(III) and Cr(VI) were 1.35 and 0.2 respectively. The effect of the acetonitrile percentages was also carried out on the speciation of arsenic only. The relative standard deviation and limit of detection were in the range of 0.01-0.02 and 0.4-1.0 mug/ml respectively. (C) 2002 Elsevier Science Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐