4.4 Article Proceedings Paper

A 32-site neural recording probe fabricated by DRIE of SOI substrates

期刊

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0960-1317/12/4/312

关键词

-

向作者/读者索取更多资源

An all-dry silicon-etch based micromachining process for neural probes was demonstrated in the manufacture of a probe with a 32-site recording electrode array. The fork-like probe shafts were formed by double-sided deep reactive ion etching (DRIE) of a silicon-on-insulator (SOI) substrate, with the buried SiO2 layer acting as an etch stop. The shafts typically had the dimensions 5 mm x 25 mum x 20 mum and ended in chisel-shaped tips with lateral taper angles of 4. An array of Ir electrodes, each 100 mum(2), and Au conductor traces were formed on top of the shafts by e-beam evaporation. An accompanying interconnect solution based on flexible printed circuitry was designed, enabling precise and flexible positioning of the probe.,, in neural tissue. SEM studies showed sharply defined probes and probe lips. The electrical yield and function were verified in bench-top measurements in saline. The magnitude of the electrode impedance was in the I MOhm range at 1 kHz, which is consistent with neurophysiological recordings.