4.3 Article Proceedings Paper

Measurement of hydroxyl radicals in pulsed corona discharge

期刊

JOURNAL OF ELECTROSTATICS
卷 55, 期 3-4, 页码 333-342

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0304-3886(01)00215-7

关键词

pulsed corona discharge; hydroxyl radical; pollution control; laser-induced fluorescence

向作者/读者索取更多资源

Hydroxyl radical generated by a pulsed corona discharge was measured by laser-induced predissociative fluorescence (LIPF) with a tunable KrF excimer laser. The LIPF with a KrF laser is a suitable method for OH observation at atmospheric pressure. It can drastically reduce the influence of undesirable quenching in the excited state. It was demonstrated that the OH-LIPF could be applied to pulsed corona discharge at atmospheric pressure. OH was observed with the LIPF in H2O/O-2/N-2 mixture. The dependence of OH yield on ambient gas composition and discharge voltage was studied. In addition, the reaction of OH with NO, a pollutant removed by non-thermal plasma, was monitored by the LIPF. Our research showed that the LIPF with a KrF laser is a useful tool for characterizing OH radicals in pulsed corona discharge. (C) 2002 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据