4.7 Article

Vascular access and increased risk of death among hemodialysis patients

期刊

KIDNEY INTERNATIONAL
卷 62, 期 2, 页码 620-626

出版社

BLACKWELL PUBLISHING INC
DOI: 10.1046/j.1523-1755.2002.00460.x

关键词

dialysis; mortality; venous catheter; infection; arteriovenous fistula; graft access

向作者/读者索取更多资源

Background. Hemodialysis with a venous catheter increases the risk of infection. The extent to which venous catheters are associated with an increased risk of death among hemodialysis patients has not been extensively studied. Methods. We conducted a retrospective cohort study of 7497 prevalent hemodialysis patients to assess the association between dialysis with a venous catheter and risk of death due to all causes and to infection. Results. A tunneled cuffed catheter was used for access in 12% of the patients and non-cuffed, not tunneled catheter in 2%. Younger age (P = 0.0005), black race (P = 0.0022), female gender (P = 0.0004), short duration since starting dialysis (P = 0.0003) and impaired functional status (P = 0.0001) were independently associated with increased use of catheter access. The proportion of patients who died was higher among those who were dialyzed with a non-cuffed (16.8%) or cuffed (15.2%) catheter compared to those dialyzed with either a graft (9.1%) or a fistula (7.3%;

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据