4.7 Article

Preparation of a sensor device with specific recognition sites for acetaldehyde by molecular imprinting technique

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 86, 期 1, 页码 20-25

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/S0925-4005(02)00107-7

关键词

molecular imprinting technique; acetaldehyde sensing; QCM sensor

向作者/读者索取更多资源

In order to prepare a quartz crystal microbalance (QCM) sensor device with an acetaldehyde-imprinted polymer layer, methyl methacrylate and ethylene dimethacrylate were polymerized with lauroyl peroxide in chloroform containing acetaldehyde. This resulted in the formation of a polymer layer having a recognition side for the acetaldehyde on the quartz crystal oscillator. When an acetaldehyde aqueous solution was dropped into the solution in which the sensor is immersed, good sensitivity and response were observed. The good selectivity was also proved by testing the sensor in an acetone, chloroform or trichloroethane aqueous solution. (C) 2002 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据