Water excitation as an alternative to fat saturation in MR imaging: Preliminary results in musculoskeletal imaging

期刊

RADIOLOGY
卷 224, 期 3, 页码 657-663

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2243011227

关键词

joints, injuries; joints, MR; magnetic resonance (MR), fat suppression; magnetic resonance (MR), technology

向作者/读者索取更多资源

Purpose: To compare fat suppression methods by using spectrally selective fat saturation and section-selective water excitation in standard magnetic resonance (MR) imaging sequences used in day-to-day musculoskeletal practice. Materials and Methods: Eighty-three patients underwent MR examination witha 1.5-T system. The two methods were compared by using three common sequences: T1-weighted spin-echo (SE) imaging performed after contrast material injection (n=24), intermediate-weighted fast SE (n=36) imaging, and T2-weighted fast SE (n=36) imaging. Acquisition times of the sequences and signal-to-noise and contrast-to-noise ratios of bone, muscle, fat, and water for the two methods were compared quantitatively. Images were then qualitatively reviewed by two radiologists who were blinded to the type of fat suppression used. Image quality was scored according to four criteria (homogeneity of fat suppression, susceptibility and foldover artifacts, conspicuousness of lesion, and overall image quality) by using a five-point scale (0, bad; 1, poor; 2, fair; 3, good; and 4, excellent). A paired Student t test was used to compare the quantitative data, and a nonparametric paired-data Wilcoxon signed rank test was used for qualitative analysis. Results: Water excitation allowed a substantial decrease in acquisition time (by up to 50%) for T1-weighted sequences. Quantitative measurements revealed a greater signal-to-noise ratio (P<.01) with water excitation for all three sequences, whereas the contrast-to-noise ratio was greater with water excitation only in intermediate-weighted sequences (P<.01). Qualitatively, water excitation proved statistically better than or equal to fat saturation for all criteria in all imaging sequences (P<.05). Mean scores of overall image quality ranged between 2.5 and 3.0 fat saturation and 3.4 and 3.7 for water excitation, respectively (P<.05). Conclusion: Section-selective water excitation is faster than conventional fat saturation and produces images of better quality. (C) RSNA, 2002.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据