Volume-dependent variations of regional lung sound, amplitude, and phase

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 93, 期 3, 页码 1030-1038

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00110.2002

关键词

respiratory mechanics; acoustics; respiratory sounds; pulmonary ventilation; signal processing; computer assistance

向作者/读者索取更多资源

Acoustic imaging of the respiratory system demonstrates regional changes of lung sounds that correspond to pulmonary ventilation. We investigated volume-dependent variations of lung sound phase and amplitude between two closely spaced sensors in five adults. Lung sounds were recorded at the posterior right upper, right lower, and left lower lobes during targeted breathing (1.2 +/- 0.2 1/s; volume = 20-50 and 50-80% of vital capacity) and passive sound transmission (less than or equal to0.2 1/s; volumes as above). Average sound amplitudes were obtained after band-pass filtering to 75-150, 150-300, and 300-600 Hz. Cross correlation established the phase relation of sound between sensors. Volume-dependent variations in phase (less than or equal to1.5 ms) and amplitude (less than or equal to11 dB) were observed at the lower lobes in the 150- to 300-Hz band. During inspiration, increasing delay and amplitude of sound at the caudal relative to the cranial sensor were also observed during passive transmission in several subjects. This previously unrecognized behavior of lung sounds over short distances might reflect spatial variations of airways and diaphragms during breathing.