期刊
HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL
卷 17, 期 7, 页码 353-356出版社
WILEY
DOI: 10.1002/hup.422
关键词
repetitive transcranial magnetic stimulation; stimulation placement; high and low frequency; side effect
The antidepressive potency of repetitive transcranial magnetic stimulation (rTMS) seems to depend on variables such as the stimulation placements, different frequencies, stimulus intensities, coil shape and interstimulus intervals. The aim of this pilot study was to investigate the augmentation properties of rTMS combining low and high frequencies. Thirty six depressed medicated in-patients were recruited and assigned to three different rTMS treatment modalities as an add-on strategy (each n = 12). In group 1 a stimulus intensity of 110% of the motor threshold (MT) was used with a frequency of 10 Hz over the left dorsolatero prefrontal cortex (DLPC). The right DLPC was stimulated in the same session with 110% MT at 1 Hz. In group 2 the patients were stimulated only over the left DLPC with alternating trains of 110% MT at 10 Hz and trains of 110% MT at 1 Hz in the same session. In group 3 the high frequency stimulation over the left DLPC was performed as an internal control group. None of the treatment modalities was superior but different side effects were observed. These preliminary findings suggest that rTMS, at varying frequencies and stimulation placements, evokes different psychoactive effects of clinical relevance. Copyright (C) 2002 John Wiley Sons, Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐