4.7 Article

FABRY-PEROT VERSUS SLIT SPECTROPOLARIMETRY OF PORES AND ACTIVE NETWORK: ANALYSIS OF IBIS AND HINODE DATA

期刊

ASTROPHYSICAL JOURNAL
卷 710, 期 2, 页码 1486-1497

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0004-637X/710/2/1486

关键词

instrumentation: interferometers; instrumentation: polarimeters; Sun: chromosphere; Sun: photosphere; Sun: surface magnetism

资金

  1. National Science Foundation

向作者/读者索取更多资源

We discuss spectropolarimetric measurements of photospheric (Fe I 630.25 nm) and chromospheric (Ca II 854.21 nm) spectral lines in and around small magnetic flux concentrations, including a pore. Our long-term goal is to diagnose properties of the magnetic field near the base of the corona. We compare ground-based two-dimensional spectropolarimetric measurements with (almost) simultaneous space-based slit spectropolarimetry. We address the question of noise and crosstalk in the measurements and attempt to determine the suitability of Ca II measurements with imaging spectropolarimeters for the determination of chromospheric magnetic fields. The ground-based observations were obtained 2008 May 20, with the Interferometric Bidimensional Spectrometer (IBIS) in spectropolarimetric mode operated at the Dunn Solar Telescope at Sunspot, NM. The space observations were obtained with the Spectro-Polarimeter of the Solar Optical Telescope aboard the Japanese Hinode satellite. The agreement between the near-simultaneous co-spatial IBIS and Hinode Stokes-V profiles at 630.25 nm is excellent, with V/I amplitudes compatible to within 1%. The IBIS QU measurements are affected by residual crosstalk from V, arising from calibration inaccuracies, not from any inherent limitation of imaging spectroscopy. We use a Principal Component Analysis to quantify the detected crosstalk. QU profiles with V crosstalk subtracted are in good agreement with the Hinode measurements, but are noisier owing to fewer collected photons. Chromospheric magnetic fields are notoriously difficult to constrain by polarization of Ca II lines alone. However, we demonstrate that high cadence, high angular resolution monochromatic images of fibrils in Ca II and H alpha, seen clearly in IBIS observations, can be used to improve the magnetic field constraints, under conditions of high electrical conductivity. Such work is possible only with time series data sets from two-dimensional spectroscopic instruments such as IBIS, under conditions of good seeing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据