4.7 Article

Evaluation of the reference tissue models for PET and SPELT benzodiazepine binding parameters

期刊

NEUROIMAGE
卷 17, 期 2, 页码 928-942

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1006/nimg.2002.1233

关键词

[I-23]iomazenil; [C-11]flumazenil; PET; SPECT; benzodiazepine receptors; reference tissue methods

向作者/读者索取更多资源

Recently, reference tissue methods have been proposed to estimate binding potential from PET data. A reference region without specifically bound ligand is used as an indirect input function to enable the expression of the time-concentration curve of a region of interest using a compartment model. However, PET dopaminergic and serotoninergic studies have shown differences between binding potential (BP) values obtained with reference tissue methods and those obtained with conventional kinetic modeling using an arterial input function. In this study, we measured the BP values for the benzodiazepine receptors in seven subjects using PET [C-11]flumazenil and SPELT [I-123]iomazenil radioligands. We compared the BP values obtained using the reference tissue methods with those obtained using the conventional kinetic method. These values were also compared with the absolute value of receptor density, B'(max). For the PET studies, a multi-injection approach employing labeled and unlabeled flumazenil was used to estimate the main binding parameters, BP and B'(max). For SPELT studies, a single injection protocol of [I-123]iomazenil was used to estimate BP values. The BP values were estimated using one- and two-tissue compartment models for the target region. Similar BP values were obtained using either the one- or two-tissue compartment model. This is probably due to the rapid equilibrium between tissue compartments reached with these radioligands. For PET and SPELT, these BP values were highly correlated (r > 0.960) to the BP values obtained using the arterial input function. We also found high correlations between the BP values obtained using the simplified reference tissue method and the receptor density parameter B'(max) (r > 0.884). However, the reference tissue methods yielded lower BP values than those obtained using the conventional approach. Moreover, there was a bias on BP values that was not a simple scaling. It seems that the physiological values found in gray matter structures using these radioligands give acceptable BP values. We conclude that the reference tissue methods should be carefully evaluated for each radioligand. (C) 2002 Elsevier Science (USA).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据