4.7 Article

Sulfate dry deposition fluxes and overall deposition velocities measured with a surrogate surface

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 297, 期 1-3, 页码 193-201

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0048-9697(02)00127-4

关键词

sulfate; dry deposition; deposition velocity

向作者/读者索取更多资源

Previous studies have shown that the dry deposition of particulate sulfate can account for a significant fraction of its total (wet+dry) deposition. However, there is no generally accepted method to directly measure dry deposition. In this study, the particulate sulfate dry deposition was measured using a smooth surrogate surface between September 2000 and June 2001 in Izmir, Turkey. Concurrently, ambient air samples were collected. Average particulate sulfate fluxes and ambient concentrations were 49.3+/-24.3 mg m(-2) d(-1) and 11.2+/-6.6 mug m(-3), respectively. The measured particulate dry deposition fluxes were higher than those measured in other urban and rural areas. The contribution of marine and terrestrial sources was also estimated and found to be insignificant. The particulate phase overall dry deposition velocities calculated using the dry deposition fluxes and corresponding ambient concentrations averaged 6.3+/-3.9 cm s(-1). This value is higher than values typically used to estimate particulate sulfate deposition; however, it is in good agreement with values determined using similar surrogate surface techniques. (C) 2002 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据