Flow injection chemiluminescence determination of hydrazine by oxidation with chlorinated isocyanurates

期刊

TALANTA
卷 58, 期 4, 页码 785-792

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0039-9140(02)00362-4

关键词

chemiluminescence (CL); chlorinated isocyanurates; hydrazine; flow injection analysis (FIA)

向作者/读者索取更多资源

A rapid and sensitive flow injection chemiluminescence (CL) method is described for the determination of hydrazine based on the CL generated during its reaction with either sodium dichloroisocyanurate (SDCC) or trichloroisocyanuric acid (TCCA) in alkaline medium. The emission intensity is greatly enhanced if dichlorofluorescein (DCF) as sensitizer is present in the reaction medium. The presence of citrate prevents the precipitation of some cations in the reaction medium and also causes an enhancement in emission intensity. The effect of analytical and flow injection variables on these CL systems and determination of hydrazine are discussed. The optimum parameters for the determination of hydrazine were studied and were found to be the following: SDCC and TCCA both 1 X 10(-3) M; NaOH, 2 x 10(-1) M; DCF, 5 X 10(-6) M; citrate, 1 X 10(-3) M and flow rate, 3.8 ml min(-1). The optimized method yielded 3sigma detection limits of 2 x 10(-7) and 3 x 10(-7) M for hydrazine with SDCC and TCCA oxidants, respectively. The method is simple, fast, sensitive, and precise and was applied to the determination of hydrazine in water samples. (C) 2002 Elsevier Science B.V. All rights reserved.