4.7 Article Proceedings Paper

Comparison of methods for particulate phase mercury analysis: sampling and analysis

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 374, 期 6, 页码 1009-1014

出版社

SPRINGER-VERLAG BERLIN
DOI: 10.1007/s00216-002-1584-4

关键词

particulate mercury; acid digestion; thermoreduction; denuder; sampling artifact

向作者/读者索取更多资源

Accurate and reliable sampling and analysis of mercury forms is an overriding aim of any atmospheric monitoring effort which seeks to understand the fate and transport of the metal in the environment. Although a fraction of the total mercury forms found in the atmosphere, particulate phase mercury, Hg-p, is believed to play a prominent role in both wet and dry deposition to the terrestrial and aquatic environments. Currently, microwave acid extraction and thermoreductive methodologies for analysis of Hg-p samples are widely used. We report on the potential for the use of a thermworeductive method for Hg-p analysis to evaluate and optimize it for use in routine monitoring networks. Pre-baked quartz filters can be placed in particulate samplers with well-characterized size cuts, such as dichotomous samplers and microoriface impactors. The thermoreductive methodology facilitates rapid analysis after sample collection. It requires no chemical extraction thereby eliminating the potential for contamination and generation of hazardous waste. Our results indicate that, on average, the thermoreductive method yields 30% lower values for fine fraction Hg-p when compared with microwave acid digestion. This may be due to matrix interferents that reduce the collection efficiency of mercury onto gold preconcentration traps. Results for total particulate mercury samples indicate that on average the thermoreductive method yields 56% lower values for the coarse fraction when compared with microwave acid digestion. Experiments were also conducted in Detroit, MI, USA to investigate whether elevated reactive gaseous mercury (Hg(2+)g) in an urban environment can lead to an artifact during the collection of filters for Hg-p analysis. Our results indicate a significantly higher amount of Hg-p collected onto a filter using the conventional methodology as compared to a filter collected downstream of KCl-coated annular denuders in the absence of Hg-g(2+). These results point to the presence of Hg-g(2+) as an artifact during Hg-p measurement. These results indicate that a denuder must be utilized upstream of a filter for Hg-p collection to prevent significant Hg-g(2+) artifact formation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据