3.8 Article

Wave pressure gauge analysis with current

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)0733-950X(2002)128:6(271)

关键词

pressure gages; wave pressures; wave height; Washington; currents

向作者/读者索取更多资源

Bottom-mounted pressure gauges are used to measure waves in coastal inlets, where tidal currents are significant. Theoretically, neglect of the current in analysis of pressure data can lead to order-one errors in wave height estimates. Wave height is overestimated by neglecting flood current and underestimated by neglecting ebb current. A collocated wave buoy and bottom-mounted pressure gauge were deployed at Willapa Bay, Washington, to evaluate the significance of including current in pressure data analysis. Wave heights were overestimated by up to 20% if current was neglected. Larger current-induced errors in wave height were prevented by truncation of high-frequency energy to exclude pressure system noise. Truncation of the spectra leads to overestimates of mean wave period and underestimates of wave height. Adding a theoretical tail to the spectra reduces truncation errors. If current measurements are not available for pressure gauge analysis, reasonable results can be achieved by applying a conservative high-frequency cutoff and adding a theoretical tail.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据