4.7 Article

A convenient assay of glycoserum by nitroblue tetrazolium with iodoacetamide

期刊

CLINICA CHIMICA ACTA
卷 325, 期 1-2, 页码 127-131

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0009-8981(02)00277-2

关键词

glycoserum; assay; nitroblue tetrazolium; iodoacetamide; thiol; uricase; detergent

向作者/读者索取更多资源

Background: To determine glycoserum, the nitroblue tetrazolium (NBT) assay is quick, economical, convenient and easily automated. This method, however, is vulnerable to interference by thiol group, which should not be ignored during the analysis. Methods: Thiol group in glycoserum was blocked with iodoacetamide (IAM) before NBT was added. The reaction was carried Out in a thermal bath and terminated on ice. The absorbance was measured at either 570 or 530 nm. Results: IAM (3-10 mmol/ 1) did not give any detectable interference in the NBT assay. The absorbance at both 570 and 530 mu was linearly related to the concentration of either glycoserum or 1-deoxy-1-morpholino-D-fructose (DMF) that had been treated with IAM. The assay showed a good discrimination between diabetic and normal subjects (t-test, P<0.001). Uric acid and lipemia under physiological conditions did not interfere with NBT reaction. The assay was affected by hyperlipemia and hematolysis. Conclusions: IAM-modified method prevented NBT assay from the interference by thiol group and uric acid. (C) 2002 Elsevier Science B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据