4.6 Article

Planck intermediate results III. The relation between galaxy cluster mass and Sunyaev-Zeldovich signal

期刊

ASTRONOMY & ASTROPHYSICS
卷 550, 期 -, 页码 -

出版社

EDP SCIENCES S A
DOI: 10.1051/0004-6361/201219398

关键词

X-rays: galaxies: clusters; galaxies: clusters: intracluster medium; galaxies: clusters: general; cosmology: observations

资金

  1. ESA member states
  2. USA (NASA)
  3. ESA
  4. CNES
  5. CNRS/INSU-IN2P3-INP (France)
  6. ASI (Italy)
  7. CNR (Italy)
  8. INAF (Italy)
  9. NASA (USA)
  10. DoE (USA)
  11. STFC (UK)
  12. UKSA (UK)
  13. CSIC (Spain)
  14. MICINN (Spain)
  15. JA (Spain)
  16. Tekes (Finland)
  17. AoF (Finland)
  18. CSC (Finland)
  19. DLR (Germany)
  20. MPG (Germany)
  21. CSA (Canada)
  22. DTU Space (Denmark)
  23. SER/SSO (Switzerland)
  24. RCN (Norway)
  25. SFI (Ireland)
  26. FCT/MCTES (Portugal)
  27. DEISA (EU)
  28. Science and Technology Facilities Council [ST/I005129/1, ST/J001562/1, ST/L001314/1, ST/J001368/1, ST/K004131/1, ST/G002916/1, ST/K006606/1, ST/H00243X/1, ST/I005765/1, ST/K001051/1, ST/J00152X/1, ST/K000985/1, ST/K000225/1, ST/J001538/1] Funding Source: researchfish
  29. UK Space Agency [ST/H001239/1, ST/J004812/1, ST/G003874/1, ST/K003674/1] Funding Source: researchfish

向作者/读者索取更多资源

We examine the relation between the galaxy cluster mass M and Sunyaev-Zeldovich (SZ) effect signal D-A(2) Y-500 for a sample of 19 objects for which weak lensing (WL) mass measurements obtained from Subaru Telescope data are available in the literature. Hydrostatic X-ray masses are derived from XMM-Newton archive data, and the SZ effect signal is measured from Planck all-sky survey data. We find an M-WL-D-A(2) Y-500 relation that is consistent in slope and normalisation with previous determinations using weak lensing masses; however, there is a normalisation offset with respect to previous measures based on hydrostatic X-ray mass-proxy relations. We verify that our SZ effect measurements are in excellent agreement with previous determinations from Planck data. For the present sample, the hydrostatic X-ray masses at R-500 are on average similar to 20 percent larger than the corresponding weak lensing masses, which is contrary to expectations. We show that the mass discrepancy is driven by a difference in mass concentration as measured by the two methods and, for the present sample, that the mass discrepancy and difference in mass concentration are especially large for disturbed systems. The mass discrepancy is also linked to the offset in centres used by the X-ray and weak lensing analyses, which again is most important in disturbed systems. We outline several approaches that are needed to help achieve convergence in cluster mass measurement with X-ray and weak lensing observations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据