4.6 Article

The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty - The posteromedial hot spot

期刊

JOURNAL OF ARTHROPLASTY
卷 17, 期 8, 页码 1033-1039

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1054/arth.2002.35796

关键词

total knee arthroplasty (TKA); varus malalignment; strain measurement

向作者/读者索取更多资源

The aim of this study was to determine the effect of varus tibial alignment on proximal tibial strain in total knee arthroplasty. Fourteen paired fresh-frozen cadaver tibiae had photoelastic coating applied. The right tibiae were cut in neutral alignment, and the left tibiae were cut in 5degrees of varus. Components were cemented and loaded with 3 x body weight, varying medial to lateral load. Surface microstrain was measured. There was a statistically increased hot spot of highly concentrated strain in the posteromedial quadrant of the proximal tibia in varus-cut bones (P<.05). In neutral alignment, the strain was nearly equal medial and lateral. The increased strain observed helps elucidate the mechanism of increased failure rates of a total knee arthroplasty inserted in varus alignment. Neutral alignment may have a protective effect.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据