Corrosion behavior of nickel-free high nitrogen austenitic stainless steel in simulated biological environments

期刊

MATERIALS TRANSACTIONS
卷 43, 期 12, 页码 3100-3104

出版社

JAPAN INST METALS & MATERIALS
DOI: 10.2320/matertrans.43.3100

关键词

nickel-free high nitrogen austenitic stainless steel; biological environment; polarization behavior; biomaterial

向作者/读者索取更多资源

The corrosion resistance of the nickel-free high nitrogen austenitic stainless steel without manganese, Fe-23Cr-2Mo-1.5N (mass%) (HNS) as biomaterials, was evaluated by the polarization test in various electrolytes: 0.9%NaCl solution (saline), phosphate buffered saline (PBS(-)), Hanks' solution (Hanks) and Eagle's minimum essential medium (E-MEM). Conventional austenitic stainless steel, 316L, was also polarized for comparison. The both alloys were spontaneously passivated in all electrolytes. The HNS didn't show pitting corrosion in the polarization range in all electrolytes although the 316L showed pitting corrosion. Passive current densities of the HNS in all electrolytes were lower than those of 316L. Therefore, the HNS shows higher passivity and resistance to pitting corrosion than 316L. The passive current density in Hanks of HNS was lower than that in saline, indicating that the protectiveness of surface oxide film increased with the existence of inorganic ions such as phosphate and calcium ions. On the other hand, the passive current density in E-MEM was higher than that in Hanks, but was lower than that in saline. Consequently, the HNS must show high corrosion resistance in vivo and be a promising biomaterials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据