4.5 Article

Validation of surface recordings of the diaphragm response to transcranial magnetic stimulation in humans

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 94, 期 2, 页码 453-461

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00581.2002

关键词

cerebral cortex

向作者/读者索取更多资源

The integrity of the central efferent motor pathways to the diaphragm can be assessed by using transcranial magnetic stimulation to measure the latency of the corresponding motor evoked potentials with surface electrodes. Because transcranial magnetic stimulation does not activate the diaphragm alone, signal contamination is a potential problem. To evaluate this issue, surface diaphragmatic motor-evoked potential latencies were compared with latencies recorded from diaphragm needle in 9 healthy volunteers. Surface latencies of muscles likely to contaminate the diaphragm signals (serratus anterior, pectoralis major, and tranversus abdominis) were also recorded. The latencies in response to nonfocal transcranial stimulation from surface electrodes were not significantly different from the needle ones (17 +/- 1.3 vs. 17.2 +/- 1.1 ms, respectively) but were significantly different from the latencies of the other muscles. In two cases, signal contamination appeared likely (serratus anterior in 1 case, abdominal muscles in 1 case). It is possible to reliably measure the latency of the diaphragm response to transcranial magnetic stimulation with adequately positioned surface electrodes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据