4.4 Article

SOLID3: A Multiplex Antibody Microarray-Based Optical Sensor Instrument for In Situ Life Detection in Planetary Exploration

期刊

ASTROBIOLOGY
卷 11, 期 1, 页码 15-28

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/ast.2010.0501

关键词

Planetary exploration; SOLID instrument; In situ automated analysis; Life-detection chips; Antibody microarrays; Environmental monitoring

资金

  1. Spanish Ministerio de Ciencia e Innovacion (MICINN) [ESP2006-08128, AYA2008_04013]

向作者/读者索取更多资源

The search for unequivocal signs of life on other planetary bodies is one of the major challenges for astrobiology. The failure to detect organic molecules on the surface of Mars by measuring volatile compounds after sample heating, together with the new knowledge of martian soil chemistry, has prompted the astrobiological community to develop new methods and technologies. Based on protein microarray technology, we have designed and built a series of instruments called SOLID (for Signs Of LIfe Detector'') for automatic in situ detection and identification of substances or analytes from liquid and solid samples (soil, sediments, or powder). Here, we present the SOLID3 instrument, which is able to perform both sandwich and competitive immunoassays and consists of two separate functional units: a Sample Preparation Unit (SPU) for 10 different extractions by ultrasonication and a Sample Analysis Unit (SAU) for fluorescent immunoassays. The SAU consists of five different flow cells, with an antibody microarray in each one (2000 spots). It is also equipped with an exclusive optical package and a charge-coupled device (CCD) for fluorescent detection. We demonstrated the performance of SOLID3 in the detection of a broad range of molecular-sized compounds, which range from peptides and proteins to whole cells and spores, with sensitivities at 1-2 ppb (ngmL(-1)) for biomolecules and 10(4) to 10(3) spores per milliliter. We report its application in the detection of acidophilic microorganisms in the Rio Tinto Mars analogue and report the absence of substantial negative effects on the immunoassay in the presence of 50mM perchlorate (20 times higher than that found at the Phoenix landing site). Our SOLID instrument concept is an excellent option with which to detect biomolecules because it avoids the high-temperature treatments that may destroy organic matter in the presence of martian oxidants.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据