4.7 Article

Determination of choline, betaine, and dimethylglycine in plasma by a high-throughput method based on normal-phase chromatography-tandem mass spectrometry

期刊

CLINICAL CHEMISTRY
卷 49, 期 2, 页码 286-294

出版社

OXFORD UNIV PRESS INC
DOI: 10.1373/49.2.286

关键词

-

向作者/读者索取更多资源

Background: The quaternary ammonium compounds, choline and betaine, and dimethylglycine (DMG) reside along a metabolic pathway linked to the synthesis of neurotransmitters and membrane phospholipids and to homocysteine remethylation and, therefore, folate status. Lack of a convenient, high-throughput method for the determination of these compounds has prevented population-based studies of their possible associations with lifestyle, nutrition, and chronic diseases. Methods. Serum or plasma samples were deproteinized by mixing with three volumes of acetonitrile that contained d(9)-choline and d(9)-betaine as internal standards. We used a normal-phase silica column for the separation of choline (retention time, 2.8 min), betaine (1.3 min), DMG (1.15 min), and internal standards, which were detected as positive ions by tandem mass spectroscopy in the multiple-reaction monitoring mode, using the molecular transitions m/z 104-->60 (choline), m/z 113-->69 (d(9)-choline), m/z 118-->59 (betaine), m/z 127-->68 (d(9)-betaine), and m/z 104-->58 (DMG). Results: For all three metabolites, the assay was linear in the range 0.4-400 mumol/L, and the lower limit of the detection (signal-to-noise ratio = 5) was less than or equal to0.3 mumol/L. The within- and between-day imprecision (CVs) was 2.1-7.2% and 3.5-8.8%, respectively. The analytical recovery was 87-105%. The fasting plasma concentrations (median, 25th-75th percentiles) were 8.0 (7.0-9.3) mumol/L for choline, 31.7 (27.0-41.1) mumol/L for betaine, and 1.66 (1.30-2.02) mumol/L for DMG in 60 healthy blood donors. In individuals who had eaten a light breakfast, plasma concentrations of all three metabolites were significantly (25-30%) higher than in fasting individuals. Conclusion: This is the first method for the combined measurement of choline, betaine, and DMG in human plasma or serum. The assay is characterized by simple sample preparation, no derivatization, high throughput, imprecision (CV) <10%, detection limits below the values seen in volunteers, and the high specificity provided by tandem mass spectroscopy. (C) 2003 American Association for Clinical Chemistry.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据