Changes in surface roughness and colour stability of soft denture lining materials caused by denture cleansers

期刊

JOURNAL OF ORAL REHABILITATION
卷 30, 期 2, 页码 125-130

出版社

BLACKWELL PUBLISHING LTD
DOI: 10.1046/j.1365-2842.2003.01014.x

关键词

damage; denture cleansers; soft lining materials; surface roughness

向作者/读者索取更多资源

Soft denture lining materials were immersed into solutions of denture cleansers for 8 h at room temperature, and immersed into distilled water for the remainder of the 24-h period at 37 degreesC. Surface roughness of the soft denture lining materials was measured by contact type surface roughness instrument. For the colour stability test, soft denture lining materials were immersed in the denture cleansers as described above for 180 days. Finally, the colour changes of each material were quantitatively measured by a photometrical instrument to obtain the colour differences between newly processed specimen and immersed specimens (P < 0.01). An autopolymerizing silicone material, Evatouch, exhibited severe changes in surface roughness by all denture cleanser, and the generic material GC Denture Relining showed the minimal changes. Severe colour changes were also observed with some liner and cleanser combinations (P < 0.01). Except for Evatouth, the four silicone soft liners were more stable in surface roughness and in colour change than the two acrylic soft liners. One autopolymerizing silicone (GC denture relining) and one heat curing silicone (Molloplast B) demonstrated the best stability.