Comparison of fixed-flexion positioning with fluoroscopic semi-flexed positioning for quantifying radiographic joint-space width in the knee: test-retest reproducibility

期刊

SKELETAL RADIOLOGY
卷 32, 期 3, 页码 128-132

出版社

SPRINGER-VERLAG
DOI: 10.1007/s00256-002-0603-z

关键词

fixed-flexion radiography; fluoroscopic semi-flexed radiography; medial femorotibial joint

资金

  1. NIAMS NIH HHS [R01 AR43791-03] Funding Source: Medline

向作者/读者索取更多资源

Objective: To compare fixed-flexion radiography of the knee with fluoroscopic semi-flexed radiography in terms of the reproducibility of measurements of minimum joint-space width (JSW) in the medial femorotibial joint. Methods: Posteroanterior radiographs of the right knees of 18 normal volunteers were acquired with the patients standing on an upright fluoroscopy table, the feet externally rotated 10degrees and the toes touching the vertical table. Knees were positioned and radiographed with two different techniques: (1) semi-flexed positioning under fluoroscopic guidance using a horizontal X-ray beam; and (2) fixed-flexion positioning, with the knees and thighs touching the vertical table, using 10degrees caudal beam angulation without fluoroscopy. Foot maps were drawn in each case. Subjects were repositioned and radiographed twice using each technique. The posteroanterior beam angle that optimally projected the medial tibia plateau with the patient in the fixed-flexion position was also determined for each subject in a separate examination using fluoroscopy. Ten patients with osteoarthritis were also examined with the fixed-flexion technique using a conventional radiographic unit. Minimum medial joint-space width (JSW) in the medial femorotibial joint was measured manually with a graduated lens and also with a semi-automated computer algorithm. Results: Reproducibility errors (root-mean-square SD) for manual and automated JSW measurement were 0.2 mm and 0.1 mm, respectively, for fluoroscopic semi-flexed positioning in volunteers; 0.3 mm and 0.1 mm, respectively, for fixed-flexion positioning in volunteers; and 0.2 mm and 0.1 mm, respectively, for fixed-flexion positioning in osteoarthritic patients. The optimal beam angle for visualizing the joint space was 9.0degrees+/-3.6degrees. Conclusion: Fixed-flexion, non-fluoroscopic radiography of the knee can provide reproducible JSW measurement using widely available X-ray equipment. This technique is more feasible for multicenter clinical studies and routine clinical use than are methods that rely on fluoroscopic alignment of the tibial plateau.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据