期刊
ENERGY AND BUILDINGS
卷 35, 期 3, 页码 273-280出版社
ELSEVIER SCIENCE SA
DOI: 10.1016/S0378-7788(02)00089-0
关键词
tropical humid regions; thermal comfort; the index PMV and PMV*; urban dwelling; numerical simulation
The air temperature and humidity combined in the enthalpy have a strong impact on the perceived air quality, and perceived air quality determines the required ventilation in ventilation standard. In tropical humid climate, which is mainly characterized by an elevated air temperature and a high relative humidity, obtaining the comfort conditions in the buildings can make by permitting sufficient interior air velocity. Air movements inside a building depend not only on external wind velocity, but also a number of architectural design element. This study aims to find out the effect of architectural design in naturally ventilated building to obtain thermal comfort in tropical humid regions. The applicability of some architectural design elements such as type and location of window, balcony configuration, and interior division was assessed using numerical simulation. The analysis shows that balcony, most window configurations and interior division plays a significant role in modifying the indoor thermal condition but it does not always need a higher air speed. (C) 2002 Elsevier Science B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐