期刊
WATER RESEARCH
卷 37, 期 6, 页码 1252-1259出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0043-1354(02)00485-2
关键词
N-15; stable isotopes; anaerobic ammonium oxidation; rotating biological contactor; RBC
High autotrophic nitrogen removal rates of 858 mg NL-1 day(-1) or 1.55 g N m(-2) day(-1) were obtained in a lab-scale rotating biological contactor treating an ammonium rich influent. It was postulated that ammonium was removed as dinitrogen gas by a sequence of aerobic ammonium oxidation to nitrite taking place in the outer biofilm layer and anaerobic ammonium oxidation with nitrite as electron acceptor occuring in the deeper biofilm layer. Chemical evidence for anaerobic ammonium oxidation within intact biofilm sludge from a lab-scale rotating biological contactor could be provided, without direct identification of responsible organisms catalysing this reaction. N-15 tracer techniques were used for identification and quantification of nitrogen transformations. In batch tests with biofilm sludge at dissolved oxygen concentrations lower than 0.1 mg L-1, ammonium and nitrite did react in a stoichiometric ratio of 1: 1.43 thereby forming dinitrogen. N-15 isotope dilution calculations revealed that anaerobic ammonium oxidation was the major nitrogen transformation leading to concomitant ammonium and nitrite removal. Isotopic analysis of the produced biogas showed that both ammonium-N and nitrite-N were incorporated in N-2. (C) 2003 Elsevier Science Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐