4.7 Article

Thermo-mechanical fatigue of single crystal nickel-based superalloy DD8

期刊

SCRIPTA MATERIALIA
卷 48, 期 9, 页码 1265-1270

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S1359-6462(03)00051-4

关键词

thermo-mechanical fatigue; superalloy; single crystal; dislocation

向作者/读者索取更多资源

The thermo-mechanical fatigue (TMF) behavior and the relevant microstructural evolution of the single crystal nickel-based superalloy DD8 were investigated. In-phase TMF lives were much shorter than those of out-of-phase TMF. The mechanism of TMF damage is discussed based on the microstructural evolution during TMF. (C) 2003 Acta Materialia Inc. Published by Elsevier Science Ltd. All rights reserved.