4.4 Article Proceedings Paper

Towards a prediction of long-term anomalous fading of feldspar IRSL

期刊

RADIATION MEASUREMENTS
卷 37, 期 4-5, 页码 493-498

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S1350-4487(03)00016-7

关键词

-

向作者/读者索取更多资源

Anomalous fading of the infrared stimulated luminescence in feldspar is described by a new equation in which the unwanted loss of luminescence is given as a function of three variables, the measured fading rate, the laboratory radiation dose rate, and the environmental radiation dose rate. This equation is labelled dose rate correction (DRC) and it is tested on (a) young sediment samples for which the radiation growth curve is in the linear part of the dose-response curve, and (b) geologically old sediments in luminescence field saturation. Most of the experimental results are consistent with predictions that can be deduced from this equation. Given the common range of dose rates in luminescence laboratories and in natural soil environments, the time necessary for the unstable luminescence generated by artificial irradiation to fade away is predicted to be ca. 10(4)-10(5) years. (C) 2003 Elsevier Science Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据