4.6 Article

A novel hydrogen peroxide sensor via the direct electrochemistry of horseradish peroxidase immobilized on colloidal gold modified screen-printed electrode

期刊

SENSORS
卷 3, 期 9, 页码 350-360

出版社

MOLECULAR DIVERSITY PRESERVATION INTERNATIONAL
DOI: 10.3390/s30900350

关键词

screen-printed electrodes; horseradish peroxidase; electrocatalysis; colloidal gold; amperometric sensors

向作者/读者索取更多资源

The direct electrochemistry of horseradish peroxidase (HRP) immobilized on a colloidal gold modified screen-printed carbon electrode (HRP-Au-SPCE) and its application as a disposable sensor were studied. The immobilized HRP displayed a couple of stable and well-defined redox peaks with a formal potential of - 0.338 V ( vs. SCE) and a heterogeneous electron transfer rate constant of (0.75 +/- 0.04) s(-1) in 0.1 M pH 7.0 PBS. It showed a highly thermal stability, fast amperometric response and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The biosensor exhibited high sensitivity, good reproducibility, and long-term stability for the determination of H2O2 with a linear range from 0.8 M to 1.0 mM and a detection limit of 0.4 M at 3sigma. The variation coefficients are 2.7 % and 2.3 % for over 10 successive assays at the H2O2 concentrations of 8.0 and 20 M, respectively. The K-M(app) for H2O2 sensor was determined to be 1.3 mM.