4.5 Article

Brain responses to micro-machined silicon devices

期刊

BRAIN RESEARCH
卷 983, 期 1-2, 页码 23-35

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/S0006-8993(03)03023-3

关键词

brain response; micro-machined silicon device; tissue-device interaction; cellular encapsulation

资金

  1. NCRR NIH HHS [RR10957, P41-RR09754] Funding Source: Medline
  2. NINDS NIH HHS [R01-NS40977] Funding Source: Medline

向作者/读者索取更多资源

Micro-machined neural prosthetic devices can be designed and fabricated to permit recording and stimulation of specific sites in the nervous system. Unfortunately, the long-term use of these devices is compromised by cellular encapsulation. The goals of this study were to-determine if device size, surface characteristics, or insertion method affected this response. Devices with two general designs were used. One group had chisel-shaped tips, sharp angular corners, and surface irregularities on the micrometer size scale. The second group had rounded corners, and smooth surfaces. Devices of the first group were inserted using a microprocessor-controlled inserter. Devices of the second group were inserted by hand. Comparisons were made of responses to the larger devices in the first group with devices from the second group. Responses were assessed 1 day and 1, 2, 4, 6, and 12 weeks after insertions. Tissues were immunochemically labeled for glial fibrillary acidic protein (GFAP) or vimentin to identify astrocytes, or for ED1 to identify microglia. For the second comparison devices from the first group with different cross-sectional areas were analyzed. Similar reactive responses were observed following insertion of all devices; however, the volume of tissue involved at early times, <1 week, was proportional to the cross-sectional area of the devices. Responses observed after 4 weeks were similar for all devices. Thus, the continued presence of devices promotes formation of a sheath composed partly of reactive astrocytes and microglia. Both GFAP-positive and -negative cells were adherent to all devices. These data indicate that device insertion promotes two responses-an early response that is proportional to device size and a sustained response that is independent of device size, geometry, and surface roughness. The early response may be associated with the amount of damage generated during insertion. The sustained response is more likely due to tissue-device interactions. (C) 2003 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据