4.4 Article

In-vivo high resolution three-dimensional MRI studies of rat joints at 7T

期刊

NMR IN BIOMEDICINE
卷 16, 期 8, 页码 484-493

出版社

JOHN WILEY & SONS LTD
DOI: 10.1002/nbm.855

关键词

7 T MRI; rat; joint; cartilage; relaxation constants; rheumatoid arthritis

向作者/读者索取更多资源

It is important to obtain high resolution images of joints for the study of disease, especially in rodent experimental models. We optimized H-1 magnetic resonance imaging three-dimensional sequences at 7 T, with lipid signal suppression, and T-1 and T-2 measurements for in-vivo experiments on rat joints, in order to assess the effectiveness of high-field MRI. The method was validated by applying it to the early diagnosis of arthritis. We studied the progress of rheumatoid arthritis in an arthritic rat model. We observed the rats' knees for 21 days after inducing arthritis. The images acquired over one hour had a high resolution of 1.75 x 10(-3) mm(3), (105 x 105 x 145 mum(3)) which allowed us to spot the early stages of joint degeneration, such as bone erosion, and to observe an apparent 'MRI' loss of cartilage thickness, attributed to dehydration of the cartilage tissue. The MR images obtained during the early stages of rheumatoid arthritis enabled us to study joint changes accurately before any histological signs of attack were visible. Copyright (C) 2003 John Wiley Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据