4.5 Article

Iontophoresis-gentamicin delivery into the rabbit cornea, using a hydrogel delivery probe

期刊

EXPERIMENTAL EYE RESEARCH
卷 78, 期 3, 页码 745-749

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/S0014-4835(03)00215-X

关键词

iontophoresis; cornea; rabbit; gentamicin

向作者/读者索取更多资源

Purpose. To evaluate the efficacy of penetration of gentamicin into the cornea of rabbits Using iontophoresis with a hydrogel-gentamicin containing probe. Methods. Eight of 10 groups (groups 3-10) of 6 rabbits (one eye per rabbit), underwent corneal iontophoresis using soft stable hydroxyethyl methacrylate hydrogel discs (80% water content) loaded with gentamicin sulphate which were mounted on in iontophoresis probe. The studied current intensities were 0, 0.1, 0.3 and 0.6 mAmp, and the durations of iontophoresis were 10 and 60 sec. Two control groups received 1.4% topical drops of gentamicin every 5 min for 1 hr (group 1) or sub-conjunctival injection of 10 mg gentamicin (group 2). Following sacrifice, aqueous humour was taken, corneas were excised, and gentamicin concentration was determined in aqueous humour and cornea samples. Results. Post-iontophoresis, the concentration of gentamicin in the corneas ranged from high (88.60 +/- 38.64 mug ml(-1)) to very low (0.10 +/- 0.89 mug ml(-1)). Both the control groups and those rabbits treated with current intensity of 0.1 mAmp or greater obtained therapeutic gentamicin levels in the corneas. Use of iontophoresis for 60 sec or current intensity greater than 0.1 mAmp obtained corneal gentamicin levels not different from sub-conjunctival injection. Application of current intensity of 0.1 mAmp or greater gave corneal gentamicin concentrations comparable to topical application of the drug, except when 0.6 mAmp were used for 60 sec (p = 0.05). Increasing current intensity or duration of iontophoresis significantly increased 0.001 for both) gentamicin penetration into the cornea. Current intensity had more influence (Beta(2) = 0.40) than duration (Beta(2) = 0.13) on drug penetration. A significant interaction was found between the duration of iontophoresis and the current intensity. Very small or no concentrations of the drug were discovered in the anterior chambers of rabbits. Conclusions. Iontophoresis using hydrogel-gentamicin probe may deliver therapeutic concentrations of gentamicin into the cornea. (C) 2003 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据