4.7 Article

The development of membrane fouling in full-scale RO processes

期刊

JOURNAL OF MEMBRANE SCIENCE
卷 232, 期 1-2, 页码 63-72

出版社

ELSEVIER
DOI: 10.1016/j.memsci.2003.11.028

关键词

fouling; modeling; water treatment; theory; reverse osmosis

向作者/读者索取更多资源

A predictive model was developed in this study for simulating the development of membrane fouling with time in full-scale RO processes. The increase in resistance was used as an indicator of membrane fouling and it enabled one to better describe membrane fouling taking place in a long membrane channel. In this model, fouling potential of a feed water was defined as the increment in membrane resistance due to a unit volume of permeate passing through the membrane, which was directly measurable with a simple filtration experiment. By employing the concept of fouling potential, fouling property of a feed water could be directly related to fouling rate on a RO membrane. The local variations in flow properties and parameters were explicitly taken into consideration in the model in order to provide a more realistic description of a full-scale RO process. The results of the simulation studies demonstrated that a full-scale RO system could maintain a constant average permeate flux for a period of time even though fouling development had occurred right from the start of operation. The effects of water fouling potential, channel length, and membrane resistance on fouling development in full-scale RO processes were investigated. (C) 2004 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据