期刊
CORROSION SCIENCE
卷 46, 期 4, 页码 795-806出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0010-938X(03)00185-9
关键词
-
The corrosion resistance of AISI 316L stainless steel for biomedical applications, was significantly enhanced by means of inorganic and hybrid SiO2 sol-gel coatings deposited by dip-coating. Coatings of 0.5-1.1 mum with different hybrid character were obtained by varying the temperature of thermal treatment from 400 to 550 degreesC. The pitting potential is increased up to I V and the current intensities were reduced up to 10(-8) A/cm(2). After one month of immersion in simulated body fluids, all the coatings showed a high degree of corrosion resistance and integrity, being slightly better the behaviour of the hybrid coatings. Not any bioactivity signal was observed. (C) 2003 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐