4.7 Article

Natural vacuum distillation technique - Part II: Experimental investigation

期刊

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
卷 28, 期 5, 页码 373-389

出版社

WILEY
DOI: 10.1002/er.969

关键词

natural vacuum; distillation; energy; evaporation; condensation

向作者/读者索取更多资源

This part of the study is concerned with the experimental investigation and uncertainty analysis of natural vacuum distillation process. Natural vacuum distillation (NVD) system is operated in the forms of free and forced mass convection. The experiments are conducted at temperatures of 20 and 40degreesC of network water as fluid in the system. During the experiments, total pressure losses are measured as 15.33 kPa during free mass convection distillation while 14 kPa during forced mass convection distillation. Depending on time and temperature, the ratios of vapour/wastewater (v/ww)(free), distilled water/wastewater (dw/ww)(forced) and total energy/distilled water (te/dw) are experimentally determined. Moreover, the ratios of mass and energy balances are experimentally obtained. Accordingly, it is found that the ratios of (dW)(forced)/(dw)(free) vary between 1.4 and 1.6 depending on the wastewater temperatures. In addition, 2.5 kWh kg(-1) distilled water is experimentally used in the NVD system with free mass convection while 2.6 kWh kg(-1) distilled water in the NVD system with forced mass convection. In case of reduction of heat and pressure losses in the systems, 0.7 kWh is needed for the former while 1.3 kWh of energy is required for the latter. Copyright (C) 2004 John Wiley Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据