4.5 Article

Hemodynamic response and oxygen transport in pigs resuscitated with maleimide-polyethylene glycol-modified hemoglobin (MP4)

期刊

JOURNAL OF APPLIED PHYSIOLOGY
卷 96, 期 5, 页码 1843-1853

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/japplphysiol.00530.2003

关键词

polyethylene glycol; 4% maleimide polyethylene glycol hemoglobin; hemoglobin; shock; blood substitutes

资金

  1. NHLBI NIH HHS [R43 HL-64996, R44 HL-62818, R01 HL-64579] Funding Source: Medline
  2. PHS HHS [R24 64395, R01 62354, R01 62318, R01 40696] Funding Source: Medline

向作者/读者索取更多资源

Cell-free Hb increases systemic and pulmonary pressure and resistance and reduces cardiac output and heart rate in animals and humans, effects that have limited their clinical development as blood substitutes. The primary aim of this study was to evaluate the hemodynamic response to infusion of several formulations of a new polyethylene glycol (PEG)-modified human Hb [maleimide PEG Hb (MalPEG-Hb)] in swine, an animal known to be sensitive to Hb-induced vasoconstriction. Anesthetized animals underwent controlled hemorrhage (50% of blood volume), followed by resuscitation (70% of shed volume) with 10% pentastarch ( PS), 4% MalPEG-Hb in lactated Ringer (MP4), 4% MalPEG-Hb in pentastarch (HS4), 2% MalPEG-Hb in pentastarch (HS2), or 4% stroma-free Hb in lactated Ringer solution (SFH). Compared with baseline, restoration of blood volume after resuscitation was similar and not significantly different for the PS (103%), HS2 (99%), HS4 (106%), and MP4 (87%) animals but significantly less for the SFH animals (66%) (P<0.05). All solutions that contained MalPEG-Hb restored mean arterial and pulmonary pressure and cardiac output. Systemic vascular resistance was unchanged, and pulmonary arterial pressure and resistance were increased slightly. Both systemic and pulmonary vascular resistance increased significantly in animals that received SFH, despite less adequate blood volume restoration. Oxygen consumption was maintained in all animals that received MalPEG-Hb, but not PS. Base excess improved only with MalPEG-Hb and PS, but not SFH. Red blood cell O-2 extraction was significantly increased in animals that received Hb, regardless of formulation. These data demonstrate resuscitation with MalPEG-human Hb without increasing systemic vascular resistance and support our previous observations in animals suggesting that the efficacy of low concentrations of PEG-Hb in the plasma results from reduced vasoconstriction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据