4.7 Article

In-service evaluation of a reinforced concrete T-beam bridge FRP strengthening system

期刊

COMPOSITE STRUCTURES
卷 64, 期 2, 页码 179-188

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.compstruct.2003.08.002

关键词

FRP strengthening system

向作者/读者索取更多资源

In November 1999, bonded fiber-reinforced polymer (FRP) laminates were used to strengthen a single span, reinforced concrete T-beam bridge in New York State. The laminate system was installed to strengthen the structure in flexure and shear, and to contain observed freeze-thaw cracking. The bridge was then instrumented and load tested before and after installation of the laminates, to evaluate effectiveness of the strengthening FRP system. In November 2001, the load test was repeated to monitor in-service performance of the system. The test results indicated that the quality of bond between the laminates and concrete, and effectiveness of the system have not deteriorated after two years of service. Further inspection using an Infrared thermography camera did not show any significant delamination in the system, in agreement with the test results. (C) 2003 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据