4.8 Article

Continuous particle separation through deterministic lateral displacement

期刊

SCIENCE
卷 304, 期 5673, 页码 987-990

出版社

AMER ASSOC ADVANCEMENT SCIENCE
DOI: 10.1126/science.1094567

关键词

-

资金

  1. NHGRI NIH HHS [HG01506] Funding Source: Medline

向作者/读者索取更多资源

We report on a microfluidic particle-separation device that makes use of the asymmetric bifurcation of laminar flow around obstacles. A particle chooses its path deterministically on the basis of its size. All particles of a given size follow equivalent migration paths, leading to high resolution. The microspheres of 0.8, 0.9, and 1.0 micrometers that were used to characterize the device were sorted in 40 seconds with a resolution of similar to10 nanometers, which was better than the time and resolution of conventional flow techniques. Bacterial artificial chromosomes could be separated in 10 minutes with a resolution of similar to12%.