4.7 Review

Analysis of myocardial perfusion MRI

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 19, 期 6, 页码 758-770

出版社

WILEY
DOI: 10.1002/jmri.20065

关键词

magnetic resonance imaging; myocardial blood flow; tracer kinetics; perfusion; coronary artery disease

资金

  1. NHLBI NIH HHS [R01 HL65580-01, R01 HL65394-01] Funding Source: Medline

向作者/读者索取更多资源

Rapid MR imaging (MRI) during the first pass of an injected tracer is used to assess myocardial perfusion with a spatial resolution of 2-3 mm, and to detect any regional impairments of myocardial blood flow (MBF) that may lead to ischemia. The spatial resolution is sufficient to detect flow reductions that are limited to the subendocardial layer. The capacity of the coronary system to increase MBF several-fold in response to vasodilation can be quantified by analysis of the myocardial contrast enhancement. The myocardial perfusion reserve (MPR) is a useful concept for quantifying the vasodilator response. The perfusion reserve can be estimated from the ratio of MBFs during vasodilation and at baseline, in units identical to those used for invasive measurements with labeled microspheres, or from dimensionless flow indices normalized by their value for autoregulated flow at rest. The perfusion reserve can be reduced as a result of a blunted hyperemic response and/or an abnormal resting blood flow. The absolute quantification of MBF removes uncertainties in the evaluation of the vasodilator response, and can be achieved without the use of complex tracer kinetic models; therefore, its application to clinical studies is feasible.