Process requirements for achieving full-flow disinfection of recirculating water using ozonation and UV irradiation

期刊

AQUACULTURAL ENGINEERING
卷 40, 期 1, 页码 17-27

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.aquaeng.2008.10.002

关键词

Ozone; Ozonation; Ultraviolet irradiation; Advanced oxidation; Bacteria inactivation; Disinfection; Recirculating system; Water reuse; Aquaculture; Process control; Oxidative reduction potential (ORP)

资金

  1. Agriculture Research Service of the United States Department of Agriculture [59-1930-5-510]

向作者/读者索取更多资源

A continuous water disinfection process can be used to prevent the introduction and accumulation of obligate and opportunistic fish pathogens in recirculating aquaculture systems (RAS), especially during a disease outbreak when the causative agent would otherwise proliferate within the system. To proactively prevent the accumulation of fish pathogens, ozonation and ultraviolet (UV) irradiation processes have been used separately or in combination to treat water in RAS before it returns to the fish culture tanks. The objective of the present study was to determine the process requirements necessary to disinfect the full RAS flow, using ozonation followed by UV irradiation, just before the flow was returned to the fish culture tank(s). We found that a proportional-integral (PI) feed-back control loop was able to automatically adjust the concentration of ozone (O(3)) generated in the oxygen feed gas (and thus added in the low head oxygenator) in order to maintain the dissolved O(3) residual or ORP at a pre-selected set-point. We determined that it was easier and effective to continuously monitor and automatically control O(3) dose using an oxidative reduction potential (ORP) probe (in comparison to a dissolved ozone probe) that was located at the outlet of the O(3) contact chamber and immediately before water entered the UV irradiation unit. PI control at an ORP set-point of 450 and 525 mv and a dissolved O(3) set-point of 20 ppb provided almost complete full-flow inactivation of heterotrophic bacteria plate counts (i.e., producing <1 cfu/mL) and improved water quality (especially color and %UVT) in a full-scale recirculating system. Achieving this level of treatment required adding a mean dose of approximately 29 +/- 3 g O(3) per kg feed. However, because water is treated and reused repeatedly in a water reuse system, the mean daily O(3) demand required to maintain an ORP of 375-525 mV (or at 20 ppb dissolved O(3)) Was 0.34-0.39 mg/L, which is nearly 10 times lower than what is typically required to disinfect surface water in a single pass treatment. These findings can be used to improve biosecurity and product quality planning by providing a means for continuous water disinfection in controlled intensive RAS. (C) 2008 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据