4.7 Article

Kelvin-cell-based metal foam heat exchanger with elliptical struts for low energy consumption

期刊

APPLIED THERMAL ENGINEERING
卷 144, 期 -, 页码 540-550

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2018.07.110

关键词

Metal foam; Heat exchanger; Kelvin-cell; Elliptical strut; Pressure drop; Heat transfer; Pumping power

资金

  1. Basic Science Research Program through the National Research Foundation of Korea (NRF) - Ministry of Education [NRF2016R1D1A1B03935729]
  2. National Research Foundation of Korea (NRF) - Korean government (MSIT) [2011-0030013, 2018R1A2B2007117]

向作者/读者索取更多资源

Conventional Kelvin-cell-based metal foam (KMF) has triangular or circular struts. This study proposes a KMF with elliptical struts instead of such struts. Two schemes of transforming a circular strut into an elliptical strut are proposed: (1) maintaining the same circumference as the circular strut cross-section and (2) maintaining the same cross-section area as the circular strut cross-section. Five KMFs with different struts were designed. The fluid flow, heat transfer, and performance characteristics of the KMFs were numerically investigated. Two dimensionless diameters for the strut section are introduced to analyze the hydro-thermal characteristics of KMFs: lambda(a), the major diameter ratio of the elliptical strut to the circular strut, and lambda(b), the minor diameter ratio of the elliptical strut to the circular strut. The major axis of all struts was set parallel to the main flow direction. The pressure drop and heat transfer characteristics of KMFs are explained by the pressure drag and friction drag. As lambda(b) decreases from 1.000 to 0.556, the pressure drop of the KMF decreases by 44% because the pressure drag and blockage ratio decrease with lambda(b).However, the decrease of lambda(b) results in decreases in the free stream velocity around the strut, which has a penalty on the heat transfer performance. This can be partially compensated by increasing lambda(a) by increasing the flow tortuosity, surface area, and separation angle. Therefore, using the scheme with the same cross-sectional area provides better performance than using the scheme with the same circumference. A KMF using the scheme with the same cross-section area scheme required 32% less pumping power than a KMF with circular struts and the same thermal resistance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据