4.7 Article

Numerical study of performance of wire mesh mist eliminator

期刊

APPLIED THERMAL ENGINEERING
卷 67, 期 1-2, 页码 214-222

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2014.02.073

关键词

Wire mesh; Droplet separation; Pressure drop; Numerical simulation

向作者/读者索取更多资源

In this paper the effects of geometry and operating conditions on the pressure drop and separation efficiency of wire mesh mist eliminator have been investigated numerically. The effects of various variables such as vapor velocity (1-20 m/s), packing density (100-250 kg/m(3)), demister thickness (300- 200 cm), wire diameter (0.1-0.3 mm), diameter of captured droplets (1-3 mm) and the geometry of wires on droplet separation efficiency and vapor pressure drop of demister have been studied in order to evaluate the demister performance. The results show the increase of separation efficiency with increasing the diameter of water droplets, vapor velocity, packing thickness and density while increasing wire diameter decreases the performance. (C) 2014 Elsevier Ltd. All rights reserved.