Effects of refrigerant charge and structural parameters on the performance of a direct-expansion solar-assisted heat pump system

期刊

APPLIED THERMAL ENGINEERING
卷 73, 期 1, 页码 522-528

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2014.07.077

关键词

Solar-assisted heat pump; Direct-expansion; Refrigerant charge; Structural parameters; Coefficient of performance

资金

  1. National Natural Science Foundation of China [51166008]
  2. Youth Science and Technology Foundation of Gansu Province [1310RJYA005]
  3. Institute of Refrigerant and Cryogenics of Shanghai Jiaotong University

向作者/读者索取更多资源

The direct-expansion solar-assisted heat pump (DX-SAHP) is widely studied as a refrigeration system, which can supply hot water for domestic use during the whole year. The system refrigerant charge and structure parameters are believed to have a great effect on the cycling thermal performance. The refrigerant mass charge including two-phase and single-phase in heat exchangers and pipes is calculated with distributed and lumped parameter approach mathematical models, respectively. Based on the system simulation program, the refrigerant distribution characteristics and system performance under varied structural parameters are obtained. The mathematical calculation results show that the 70%-80% refrigerant charge exists in the condenser and collector; the optimum refrigerant charge, solar collector area, condenser pipe length and condenser internal diameter for the system are 1.65-1.75 kg, 6.0 m(2), 70 m and 9 mm, respectively. In the optimum parameters, the better system performance and feasible cost can be achieved. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据